Instructions
1. Put the cartridge on some paper towels in an area where you can tolerate a spill.
2. Peal off the top label. 
3. Fill the syringe with 5 ml. of color ink.
4. Very S-L-O-W-L-Y inject ink into each chamber until the sponge full. A little ink might come out of the top when full, so cover up the other two holes while filling one.
5. When finished, replace the top label.
6. Replace the cartridge and run 1 - 3 cleaning cycles as per printer instructions.
If necessary leave cartridge in printer for up to 24 hours.
The cartridge will print just like a new one. Even though the cartridge prints good, the ink level gauge will not read full after a refill. To reset the ink level gauge back to full follow these instructions:
#57 C6657
This will allow you to reset the ID system & Ink Level Indicator built into the printer.
RESETTING
1. Remove cartridge from your printer.
2. Place a piece of tape over the top left contact as shown in red on the picture to the right.
3. With the tape covering the contact place cartridge back into printer.
4. The printer will perform and alignment page.
5. Once an alignment page has been printed remove cartridge from printer.
6. Place a piece of tape over the second contact shown in red.
7. Place cartridge into printer with both pieces of tape. (One covering the first contact and one cover the second contact.)
8. Printer will print another alignment page.
9. Once the second alignment page has been printed remove cartridge from printer.
10. Remove tape pieces from cartridge contacts (Make sure there is no residual adhesive on cartridge contacts.)
11. Place cartridge into printer. Cartridge should now read full.

Additional Notes:
As stated above it is very important that there is no residual adesive on the cartridge contact point. This will make reading the cartridge difficult.
|